ASTM G154測試標準
本頁面標準信息均來源于網絡收集,或由參與標準制定的供應商提供,只作為參考使用,為確保測試結果的準確性、節省您的時間,如需ASTM G154標準詳細信息或ASTM G154具體測試方法,歡迎致電【0769-83730866】與我們技術人員聯系或給我們留言,我們將為您相關的技術支持。
ASTM G154標準介紹
ASTM G154是使用熒光紫外線設備對非金屬材料進行曝露的測試方法,現行*近版本的為2016修訂的ASTM G154-16標準。
ASTM G154是使用熒光紫外燈和冷凝裝置進行曝露測試的基本原則和操作程序,旨在再現材料曝露在陽光下(直接或透過窗玻璃)和曝露在濕氣中(雨水或露水)發生的老化效果。
Q8-UV紫外老化試驗箱用于ASTM G154 Cycle1的測試方法
Q8-UV紫外老化試驗箱用于ASTM G154 Cycle1的測試方法
Q8-UV紫外老化試驗箱用于ASTM G154 Cycle2的測試方法
Q8-UV紫外老化試驗箱用于ASTM G154 Cycle2的測試方法
Q8-UV紫外老化試驗箱用于ASTM G154 Cycle3的測試方法
Q8-UV紫外老化試驗箱用于ASTM G154 Cycle3的測試方法
ASTM G154 標準英文版本(摘抄)
1. Scope
1.1 This practice is limited to the basic principles for operating a fluorescent UV lamp and water apparatus; on its own, it does not deliver a specific result.
1.2 It is intended to be used in conjunction with a practice or method that defines specific exposure conditions for an application along with a means to evaluate changes in material properties. This practice is intended to reproduce the weathering effects that occur when materials are exposed to sunlight (either direct or through window glass) and moisture as rain or dew in actual usage. This practice is limited to the procedures for obtaining, measuring, and controlling conditions of exposure.
Note 1: Practice G151 describes general procedures to be used when exposing nonmetallic materials in accelerated test devices that use laboratory light sources.
Note 2: A number of exposure procedures are listed in an appendix; however, this practice does not specify the exposure conditions best suited for the material to be tested.
1.3 Test specimens are exposed to fluorescent UV light under controlled environmental conditions. Different types of fluorescent UV lamp sources are described.
Note 3: In this standard, the terms UV light and UV radiation are used interchangeably.
1.4 Specimen preparation and evaluation of the results are covered in ASTM methods or specifications for specific materials. General guidance is given in Practice G151 and ISO 4892-1.
Note 4: General information about methods for determining the change in properties after exposure and reporting these results is described in ISO 4582 and Practice D5870.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.7 This standard is technically similar to ISO 4892-3 and ISO 16474-3.
2. Referenced Documents
ASTM Standards
D5870 Practice for Calculating Property Retention Index of Plastics
D6631 Guide for Committee D01 for Conducting an Interlaboratory Study for the Purpose of Determining the Precision of a Test Method
G113 Terminology Relating to Natural and Artificial Weathering Tests of Nonmetallic Materials
G151 Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources
G177 Tables for Reference Solar Ultraviolet Spectral Distributions: Hemispherical on 37 Tilted Surface
ISO Standards
ISO 16474-3 Paints and VarnishesMethods of Exposure to Laboratory Light SourcesPart 3: Fluorescent UV Lamps
ISO4582 PlasticsDetermination of the Changes of Colour and Variations in Properties After Exposure to Daylight Under Glass, Natural Weathering or Artificial Light
ISO4892-1
▼ASTM G154第三方檢測機構
以上標準信息來自互聯網搜索整理,如需了解完整的ASTM G154的信息或ASTM G154標準解讀,歡迎致電【0769-83730866】詳詢。